News

Leading Supplier of Chromatography Consumables since 2007.
Position :
Home » News (Page 9)
The Role of Septum Inertness in Minimizing Sample Carryover in LC-MS
The Role of Septum Inertness in Minimizing Sample Carryover in LC-MS
2023 10 08
CARRYOVER MITIGATION USING NEEDLE WASH SOLVENT CHEMISTRY AND improved carryover mitigation in LC applications. Carryover has many sources, but the most common source of carryover is related to the autosampler and occurs when sample components adhere to or absorb onto the outside of the needle. A key attribute of modern autosamplers is the ability to effectivity remove sample from all active surfaces of the Simplifying GC Syringes and Sample Introduction – Aijiren • Can change to sampl...
View More
The Role of Septum Inertness in Minimizing Sample Contamination in Environmental Testing
The Role of Septum Inertness in Minimizing Sample Contamination in Environmental Testing
2023 10 08
An Aijiren Septum is Not Just a Septum The septum forms a barrier between your sample analyte in the vial and the outside atmosphere. This barrier protects your sample from external contamination while allowing a needle (from a manual or automatic syringe) to enter the vial, and extract the sample for the next stage of separation. Ecotoxicity and bioremediation potential assessment of soil Jan 22, 2022 · Purpose The aim of the present study was to evaluate the toxicity and biodegradation p...
View More
PTFE/silicone septa for chromatography instruments vial material
PTFE/silicone septa for chromatography instruments vial material
2023 10 08
Septa Selection Guide – Thermo Fisher Scientific PTFE silicone/ PTFE Thin, fragile needle? Soft and thin septa required e.g. silicone/ PTFE Blunt, thick needle? Slit/pre- cut liner as penetration aid (HPLC) silicone/ PTFE, slit Critical analysis? Very clean liner required 22 mm x 0.125 mm PTFE/Silicone Septa for Headspace Vials, 72 Headspace Silicone Convenience Kit contains everything you need to run Gas Chromatography. Each product is manufactured using strict quality control standa...
View More
Septum Vial Cap: Selecting the Right Material for Sample Containment and Integrity
Septum Vial Cap: Selecting the Right Material for Sample Containment and Integrity
2023 10 08
Cat Vials Sample Containment Solutions 5994 4803EN Aijiren Aijiren vials offer the same highly consistent performance across the entire size range, from 15 µL to 60 mL. Use the diagram below as a starting point for choosing the size you need based on your sample volume. 2 mL. 15 µL Sample Volume 60 mL. 4 mL 6 mL Headspace vials 40 mL. Septa Selection Tool | Thermo Fisher Scientific – IN The septum you choose for your autosampler vial can impact sample evaporation, sample security, need...
View More
How to clean silicone septa for lab equipment
How to clean silicone septa for lab equipment
2023 10 08
How to Minimize Septum Problems in GC | American Laboratory Sep 1, 2005 · Clean the insert/liner and replace the insert in a timely fashion. Glass wool or the whole insert can be replaced; inserts can be cleaned in an ultrasonic bath or thrown away. Replace the septum on time; do not wait until it has begun to leak. Septum Selection Guide Vials and Closures – Fisher Sci elastomer to the solvent. PTFE/Silicone septa are ideal for use in most HPLC and GC applications where resealability...
View More
PTFE/silicone septa for chromatography system vial cap dimensions
PTFE/silicone septa for chromatography system vial cap dimensions
2023 10 08
Thermo Scientific 11 mm Autosampler Vial Crimp Caps PTFE Minimize contamination from handling with convenient, pre-assembled Thermo Scientific™ 11 mm Autosampler Vial Crimp Caps, compatible with most HPLC and GC autosamplers. Choose from Thermo Scientific™, National™ or Chromacol™ brands. Anodized aluminum seals fit all 11mm crimp-top vials TurboMatrix Consumables Guide (009709C 01) – PerkinElmer PTFE/Butyl (gray) Aluminum Cap N9302981 PTFE/Butyl (Pharma Fix Septa) Aluminum Cap N93062...
View More
PTFE Septa for Pharmaceutical Applications: Maintaining Sample Integrity and Regulatory Compliance
PTFE Septa for Pharmaceutical Applications: Maintaining Sample Integrity and Regulatory Compliance
2023 10 08
Sample handling solutions – Fisher Sci make PTFE/silicone septa suitable for all types of chromatographic applications . A thin film of PTFE is laminated to the side of the septum that faces the sample to limit exposure of the elastomer to the solvent . PTFE/Silicone septa are ideal for use in most HPLC and GC applications where resealability and purity are critical . Pre-slit PTFE Accessory Product Data Sheet – .NET Framework PTFE/Red Rubber Septa: PTFE/Red Rubber septa are the...
View More
40% larger opening amber crimp top vials magnetic cap
40% larger opening amber crimp top vials magnetic cap
2023 04 28
Crimp Top Vial | DWK Life Sciences Crimp top vials provide an excellent seal for long term sample storage and analyses involving high volatile solvents 40% larger opening improves sample accessibility and reduces the risk of autosampler needle damage Packed in re-closable, tamper-proof evident PP-boxes for protection against contaminationduring transportation and storage 40% larger opening autosampler crimp neck vial magnetic cap 40% larger opening autosampler crimp vial silver aluminum 2022...
View More
USA crimp seal vial manufacturer
USA crimp seal vial manufacturer
2023 04 28
Flip-Off® CCS Seals – West – West Pharmaceutical Services Apr 13, 2021 · It is also compatible with glass or Daikyo® Cyrstal Zenith® vials. West’s use of TruEdge® technology provides a seal quality of proven consistency, improving machinability performance as well as user safety and convenience. Our tightest cleanliness specifications for seals help maximize patient safety. The pros and cons of crimp vs screw top vials Jan 26, 2010 · Some instruments require magnetic sea...
View More
PTFE/red rubber septa 11.6*32mm crimp neck vial for sale
PTFE/red rubber septa 11.6*32mm crimp neck vial for sale
2023 04 28
Red Rubber Septa at Thomas Scientific Specially engineered to fit standard taper joints and tubes. Manufactured under white room conditions for extreme cleanliness. Made of a more dense rubber, low extractables and a better fit (50% to 80% on joints) these septa are much less likely to fail in the presence of solvents. Compare this item. Crimp seals, 11 mm, with PTFE/rubber septa – Sigma-Aldrich Crimp seals, 11 mm, with PTFE/rubber septa, silver aluminum seal, opening size 5.5 mm, diam...
View More
Copyright 2021 Zhejiang Aijiren Technology, Inc. All Rights Reserved.