An Aijiren Septum is Not Just a Septum The septum forms a barrier between your sample analyte in the vial and the outside atmosphere. This barrier protects your sample from external contamination w...
Product Introduction

An Aijiren Septum is Not Just a Septum

The septum forms a barrier between your sample analyte in the vial and the outside atmosphere. This barrier protects your sample from external contamination while allowing a needle (from a manual or automatic syringe) to enter the vial, and extract the sample for the next stage of separation.

Ecotoxicity and bioremediation potential assessment of soil

Jan 22, 2022 · Purpose The aim of the present study was to evaluate the toxicity and biodegradation potential of oil hydrocarbons contaminated soil samples obtained from different depths at an oil refinery station area. An approach involving chemical, microbiological, respirometry and ecotoxicity assessment of soil polluted by oil hydrocarbons was adopted, in order to determine the biodegradability of

Septa Selection Guide - Aijiren Tech Scientific

chemical characteristics. The septum is provided with a thin 0.005” PTFE layer laminated to highly pure silicone, and slit through the center for easier needle penetration and to release the vacuum that forms when a large volume of sample is withdrawn from a vial. This septum provides chromatographic characteristics similar to that of a

Understanding Microbiological Sampling and Testing

• Small sample or sampling method may not be ideal for detection –e.g., small swab device or environmental area sampled • Sanitizer or residual antimicrobial chemicals might interfere with the test –Insufficient drip time prior to carcass sample collection –Excessive liquid carryover for parts sample collection

Environmental Sampling | FDA

During inspections, the FDA may collect samples from the environment in a building where foods are produced (a manufacturing plant or a commercial kitchen, for instance) to determine whether that

VOC Guidelines - USGS

Sites directly upstream or downstream of confluences or direct sources of contamination also should be avoided to minimize problems caused by backwater effects or poorly mixed flows. In addition, samples collected downstream from a bridge can be contaminated by runoff from the road surface.

Aseptic Technique for Microbiological Testing - Pharma Beginners

Sep 23, 2020 · Culturing of Biological Indicators, Bioassays and the other testing. The aseptic technique described herein is provided as a foundation to be practiced with all microbiological sampling and testing to prevent contamination of test samples and to minimize the possibility of mixed (contaminated) cultures.

Cleaning and disinfection of environmental surfaces in the

with surface contamination that was linked to subsequent infection transmission in other coronaviruses. Therefore, this guidance aims to reduce any role that fomites might play in the transmission of COVID -19 in health- care. 3. and non- health care settings. 4. Environmental surfaces -care settings in healthinclude

Contaminant Detection and Sampling and Analysis | US EPA

May 29, 2023 · EPA supports its responders' ability to characterize site contamination by developing sampling protocols, sample preparation methods, and analytical methods for chemicals, biotoxins, microbial pathogens, and radiological agents.

A fast, reliable and easy method to detect within-species DNA

Nov 9, 2020 · (B) Results for 10% contamination. The algorithm is able to distinguish the two distributions but since the score obtained by the non-contaminated sample is close to that of the 10% contaminated sample, we cannot exclude the presence of FPs if the threshold is chosen to detect 10% contamination. (C) Results for 20% contamination.

Understanding the GC Inlet - Aijiren

Split Injections - Inertness More inert than splitless • Higher velocity through the inlet • Less exposure to inlet hardware Glass wool is a compromise • Exhibits some activity • Greatly improves fluidic performance –mixing of the vaporized sample is important for uniform splitting

Microbiological environment monitoring of aseptic processing

and preparation, taxonomy, and sterilization. The staff responsible for supervision and testing should have academic training in medical or environmental microbiology. Sampling personnel as well as individuals working in clean rooms should be knowledgeable about their responsibilities in minimizing the release of microbial contamination.

Sample Canister Evaluation and Inertness Certification

Oct 5, 2018 · Entech Newsletter & Social Stream. Home / Sample Canister Evaluation and Inertness Certification. Introduction. Stainless steel canisters offer a tremendous advantage over other air sampling media, namely Tedlar® bags and adsorbent traps. When canisters were first introduced, the “SUMMA” passivated canister was the only option available.

Reducing Contamination in Forensic Investigations

Aug 11, 2021 · Barrier clothing to prevent direct contact between individuals working on a scene and the exhibits is one of the most important steps in reducing contamination. The clothing required at crime scenes can include a face mask, hair cover, two pairs of gloves, an over-suit, and overshoes. Face masks and gloves can be considered the most important

How to Avoid Contamination in Lab Samples - Aurora Biomed

Sep 29, 2019 · Check your water supply. If all of your samples including your negative control have been contaminated then it could be your water supply. In the lab, deionized water and distilled water are normally used to prevent contamination. However, your machine that makes your purified water may need to be serviced or repaired.

Related Products
Send us a message
Zhejiang Aijiren Technology, Inc. is a global supplier of life-science, chemistry, laboratory consumables, etc. Our major products are high performance liquid chromatography & gas chromatography consumables such as Chromatography Autosampler Vials with closures, inserts, crimper and syringe filters, etc; Water analysis consumables such as COD test tube.